ETATRON PERISTALTIC
BROCHURE
|
|
.
|
|

|
|
B-F
SERIES
|
|
..
|
|
|
|
.
|
|
- Dimensions: 137 (height) x 90 (width) x 109
(depth) mm.
|
|
.
|
|
|
|
|
|
|
|
.
|
|
(Looks may vary,
depending on model and variation)
|
|
.
|
|
.
|
|
COMMENTARY
|
|
.
|
|
The B-F series are fixed-flow
rate peristaltic pumps enclosed in an IP67 plastic casing, designed
primarily for cooling tower and washing machine use. As in all our new ranges of peristaltic pumps, this pump has its motor
shaft (axle of rotating head) SUPPORTED AT BOTH ENDS. This gives better
durability and resistance to wear and tear as compared with most other
peristaltic pumps, which have their motor shafts usually supported only on
one end.
(When supported at one end,
the motor shaft bends with time - due to wear and tear, or over-pressure in
the tubing’s. Symptoms of such damage is loss of
flow rate, because the pump head rollers is no longer able to squeeze on
the pump head tubing).
|
|
.
|
|
Another feature which makes the B-F series
special is the ability to discharge with pressure.
|
|
.
|
|
|
GENERAL
|
|
.
|
|
|
Series Name
|
:
B-F
|
|
Type
|
:
Peristaltic pump
|
|
Mounting
|
:
Wall-mounted
|
|
Electrical
|
:
230V, 50/60Hz, 1 ph / 12-24 VDC / other options available
|
|
Power
|
:
3.5 watts (AC supply) to 1.0 watt (DC supply)
|
|
Casing
|
:
Plastic (IP67)
|
|
Nett weights
|
:
0.3 kg
|
|
|
.
|
|
|
.
|
|
.
|
|
CONTROL TYPES AVAILABLE
|
|
.
|
|
These
are fixed-speed peristaltic pumps, usually controlled by an external timer
(option) or by an on/off output relay from the customer's process.
|
|
.
|
|
|
.
|
|
.
|
|
MODELS AVAILABLE
|
|
|
|
|
|
|
|
|
|
1.0 l/hr @ 3 bar
(fixed flow rate)
|
|
|
|
|
|
2.0 l/hr @ 2 bar
(fixed flow rate)
|
|
|
|
|
|
4.0
l/hr @ 1 bar (fixed flow rate)
|
|
|
|
|
|
6.0 l/hr @ 1 bar
(fixed flow rate)
|
|
|
|
|
|
.
|
|
|
|
|
.
|
|
.
|
|
FEATURES
|
|
|

|
|
|
|
|

|
|
|
|
|
Pump
head axle is supported at both ends, providing better durability. Most
other peristaltic pumps have their pump head axles supported only on one
side - which is the most common cause of breakdowns, when wear and tear
bends the axle.
|
|
|
|
|
New
pump head design with four rollers provides is constructed of stronger
materials and provides better efficiency.
|
|
|
|
|
Mounting
bracket is included for easy installation and removal at site.
|
|
|
|
|
|
|
|
|
|
For more information contact I.C.E
ICE Home Page
Copyright, 2007 International Chemicals Engineering Pty Ltd. |